Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Brain Sci ; 12(2)2022 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-35203907

RESUMEN

Animal studies have discovered that noise, even at levels that produce no permanent threshold shift, may cause cochlear damage and selective nerve degeneration. A hallmark of such damage, or synaptopathy, is recovered threshold but reduced suprathreshold amplitude for the auditory brainstem response (ABR) wave I. The objective of the present study is to evaluate whether the ABR wave I amplitude or slope can be used to diagnose tinnitus in humans. A total of 43 human subjects, consisting of 21 with tinnitus and 22 without tinnitus, participated in the study. The subjects were on average 44 ± 24 (standard deviation) years old and 16 were female; a subgroup of 19 were young adults with normal audiograms from 125 to 8000 Hz. The ABR was measured using ear canal recording tiptrodes for clicks, 1000, 4000 and 8000 Hz tone bursts at 30, 50, and 70 dB nHL. Compared with control subjects, tinnitus subjects did not show reduced ABR wave I amplitude or slope in either the entire group of 21 tinnitus subjects or a subset of tinnitus subjects with normal audiograms. Despite the small sample size and diverse tinnitus population, the present result suggests that low signal-to-noise ratios in non-invasive measurement of the ABR limit its clinical utility in diagnosing tinnitus in humans.

2.
Ann Otol Rhinol Laryngol ; 127(4): 285-290, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29436237

RESUMEN

OBJECTIVES: Aneurysmal bone cysts (ABC) are benign, rapidly growing osteolytic lesions. Solid variant of ABC (SVABC) is a rare subtype of ABC that has not been reported in the temporal bone. METHODS: We report the case of a 6-year-old boy presenting with a slowly enlarging bony protuberance over the right zygomatic/malar eminence region. Computed tomography and magnetic resonance imaging demonstrated a 2.6 × 5.8 × 5.1 cm temporal bone mass involving the right mastoid, petrous, and temporal squamosal calvarium, with extradural intracranial extension to the middle cranial fossa. RESULTS: The patient underwent preoperative embolization of feeder arteries followed by combined neurosurgical and neurotologic resection. Histopathology revealed characteristic ABC features with interspersed areas of intralesional osteoid formation. CONCLUSION: Solid variant of ABCs are rare lesions of the skull base that present a diagnostic challenge given their unique radiographic and histologic features. Thorough cytogenetic evaluation is warranted to rule out potential malignant secondary causes. Early surgical resection is essential due to the risk of intracranial extension. This is the first report of ABC of any type with concurrent involvement of the squamous, mastoid, and petrous portions of the temporal bone and the first report of SVABC of the temporal bone.


Asunto(s)
Quistes Óseos Aneurismáticos , Embolización Terapéutica/métodos , Procedimientos Neuroquirúrgicos/métodos , Hueso Temporal , Quistes Óseos Aneurismáticos/diagnóstico , Quistes Óseos Aneurismáticos/fisiopatología , Quistes Óseos Aneurismáticos/cirugía , Niño , Disección/métodos , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Cuidados Preoperatorios/métodos , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/cirugía , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
3.
J Diabetes Sci Technol ; 8(1): 109-116, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24876546

RESUMEN

OBJECTIVE: A prototype tear glucose (TG) sensor was tested in New Zealand white rabbits to assess eye irritation, blood glucose (BG) and TG lag time, and correlation with BG. METHODS: A total of 4 animals were used. Eye irritation was monitored by Lissamine green dye and analyzed using image analysis software. Lag time was correlated with an oral glucose load while recording TG and BG readings. Correlation between TG and BG were plotted against one another to form a correlation diagram, using a Yellow Springs Instrument (YSI) and self-monitoring of blood glucose as the reference measurements. Finally, TG levels were calculated using analytically derived expressions. RESULTS: From repeated testing carried over the course of 12 months, little to no eye irritation was detected. TG fluctuations over time visually appeared to trace the same pattern as BG with an average lag times of 13 minutes. TG levels calculated from the device current measurements ranged from 4 to 20 mg/dL and correlated linearly with BG levels of 75-160 mg/dL (TG = 0.1723 BG = 7.9448 mg/dL; R2 = .7544). CONCLUSION: The first steps were taken toward preliminary development of a sensor for self-monitoring of tear glucose (SMTG). No conjunctival irritation in any of the animals was noted. Lag time between TG and BG was found to be noticeable, but a quantitative modeling to correlate lag time in this study is unnecessary. Measured currents from the sensors and the calculated TG showed promising correlation to BG levels. Previous analytical bench marking showed BG and TG levels consistent with other literature.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...